MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Identity:
Product ID: 117- 0235
MSDS No.
Issued: 12/16/97
7214 Black Toner
CP-310
Supersedes:
none
Synonyms
& Common
Date:
12/16/97
Names:
Toner, Black Toner
Prepared by:
Lanier QA/EH&S Department
Uses:
M7214 Copier
Mixture
European
Contact:
Lanier Worldwide, WSM Europe,
Walter Fricke,
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Chemical
Formula:
Section 2: Composition / Information on Ingredients
PERCENT
CAS No.
29497-14-1
EXPOSURE LIMITS
SOURCE
Styrene butylacrylate-
butylmethaacrylate
copolymer
not listed
n/a
> 90.0
Polystyrene
Carbon black
Polypropylene
Organic ammonium salt
9003-53-6
1333-86-4
9003-07-0
102561-46-6
not listed
n/a
3.5mg/m3 3.5mg/m3
OSHA PEL ACGIH TLV
< 6.0
< 1.0
< 2.0
not listed
not listed
n/a
n/a
*PEL as the product: 15mg/m3 (total dust), 5mg/m3 (respirable dust)
*TLV as the product: 10mg/m3 (total dust), 5mg/m3 (respirable dust)
Section 3: Hazards Identification
Hazard Rating:
FIRE = 1
HEALTH = 1
REACTIVITY = 0
SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to
any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test
toner revealed there were no lung changes at all in the lowest exposure level (1mg/m3), the most relevant level to potential human
exposures. A very slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m3), while a slight
degree of fibrosis was observed at the highest exposure level (16mg/m3) in all animals. These findings are attributed to “Lung
Overloading”, a generic response to excessive amount of any dust retained in the lungs for a prolonged interval. The special test
toner was ten times more respirable than commercially available toner to comply with EPA testing protocol and would not function
properly in xerographic equipment.
Section 4: First Aid Measures
Remove to fresh air if effects occur. Consult
local medical personnel
Inhalation:
Eye Contact: In case of contact, immediately flush eyes with
water for 5 minutes.
Ingestion: Rinse mouth with water. Call a physician.
Skin Contact:
Wash with soap and water.
1
|
Kustom Stereo Amplifier Sienna30 User Manual
Learning Resources Model Vehicle LER 0343 User Manual
Lightolier Indoor Furnishings 1101FRD User Manual
Lindy Mouse 20599 User Manual
Linksys Network Card NSLU2 User Manual
Makita Planer 1805B User Manual
Makita Power Hammer HR2450FT User Manual
Meco Gas Grill 67A4T09K21 User Manual
Mellerware Iron 23250 User Manual
Memorex Portable CD Player MKS2420 User Manual